Globe Valves with Linear Actuators

  • Overview
  • Description
  • Main Features
•  Kvs : 3,8 5,1 9,4 15,4 22,2 40,1 63,4 89,7 136,7
•  Sizes : DN 15 DN 20 DN 25 DN 32 DN 40 DN 50 DN 65 DN 80 DN 100
Bonnet : Standard – up to 220 ēC;
•  Stem Sealing : PTFE/GR V-Rings – up to 220 ēC. Graphite – up to 300 ēC.
•  Port : Full port
Max air Supply : 3,5 bar.
•  Material : PV25G-OF – SG iron. PV25I-OF – stainless steel
The PV25 On-Off valves are single seated, two-way body constructed with in-line straight connections. The PA pneumatic actuator comprises a rubber diaphragm and multi-springs. Its action can be DA – direct action (air to close) or RA – reverse action (air to open). Their wide application ranges allow the use of this valve with the most common process fluids such as water, superheated water, steam, air, gas and other non corrosive fluids.
Single seated, two way, direct or reverse action valve.
Valve top flange permanently attached to the body, removal is unnecessary for replacing the actuator.
Soft sealing as standard.
Sterilize workpieces

 
QIS_SERIES_pump

Globe Valves with Linear Actuators

  • Overview
  • Description
  • Main Features
•  Kvs : 3,8 5,1 9,4 15,4 22,2 40,1
•  Sizes : DN 15 DN 20 DN 25 DN 32 DN 40 DN 50
Bonnet : Standard – up to 220 ēC;
•  Stem Sealing : PTFE/GR V-Rings – up to 220 ēC. Graphite – up to 300 ēC.
•  Port : Full port
Max air Supply : 3,5 bar.
•  Material : PV40S and EV40S – steel. PV40I and EV40I – stainless steel.
The PV40 control valves are single seated, two-way body constructed with in-line straight connections. The PA pneumatic actuator is rubber diaphragm and multi-springs. Its action can be DA – direct action (air to close) or RA – reverse action (air to open). The PV40 valves have been designed to ensure an accurate control in any process condition. Their wide application ranges allow the use of this valve with the most common process fluids such as water, superheated water, steam, air, gas and other non corrosive fluids.
Single seated, two way, direct or reverse action valve.
Valve top flange permanently attached to the body, removal is unnecessary for replacing the actuator.
Metal to metal sealing as standard.

INTERMITTENT BLOWDOWN VALVES

  • Overview
  • Description
  • Main Features
•  Kvs : 6,3 16
•  Sizes : 3/4” – DN 20 1” – DN 25 DN 32 11/2” – DN 40 2” – DN 50
Bonnet : Standard – up to 220 ēC;
•  Stem Sealing : PTFE/GR V-Rings – up to 220 ēC. Graphite – up to 300 ēC.
•  Port : Full port
Manual Operation : Hand ,Foot
•  Material : VPA26/2S – carbon steel. VPA26/2I – stainless steel.
The VPA26/2 blowdown valve series were specially designed for application on steam boilers, to remove sludge sediments which naturally settle on the bottom of the boiler. These intermittent valves operate manually or automatically with timed control. This valve is available with a diaphragm actuator and/or manual operation lever.
High quality hardened valve seat and plug.
Manual or automatic intermittent timed control.
Lockable in open position if supplied with manual operation lever.
Practical foot operated lever.
Maintenance free stem sealing.
Tool-free quick exchangeable clamped-in seats, allowing fast and easy in-site maintenance procedures.

Three Way Control Valve

  • Overview
  • Description
  • Main Features
•  Kvs : 4 6,3 10 16 25 40
•  Sizes : DN 15 DN 20 DN 25 DN 32 DN 40 DN 50
Bonnet : Standard – up to 220 ēC;
•  Stem Sealing : PTFE/GR V-Rings – up to 220 ēC. Graphite – up to 300 ēC.
•  Port : Full port
Max air Supply : 3,5 bar.
•  Material : PV403S and EV403S – steel. PV403I and EV403I – stainless steel
The PV403 control valves are three-way valve body for mixing service. The PA pneumatic actuator is rubber diaphragm and multi-springs. Its action can be DA – direct action (air to close) or RA – reverse action (air to open). The V403 valves have been designed to assure an accurate control in any process condition. Their wide application ranges allow the use of this valve with the most common process fluids such as water, superheated water, diathermic oil, steam, air, gas and other non corrosive fluids.
Mixing or diverting control valve.
Standard packing or bellows sealed stem sealing.
Logo FDA iso flag

 

 

 

 

We offer a full range of T-316L stainless steel clean steam thermostatic traps to handle the special requirements of clean steam systems. Different body configurations allow choice of piping and ease of cleaning. The thermostatic design is free-draining and can operate close to steam temperature at any given pressure..